Ultra-High Temperature Heat Pumps

75oC to 85oC High Temperature Hot Water.

thermace 1 scaled e1714714213152 500x123 - Solutions - High Temperature Heat Pumps

Ultra-High Temperature Heat Pumps

Although Toyesi has been manufacturing heat pumps for over 30 years, sometimes you need to turn to alternative suppliers for solutions to fit a unique situation.  A growing trend to change over from high-temperature gas-based boiler systems to alternatives such as heat pump systems required working with a key market leading manufacturers overseas.

Turning of the Gas?

With the awareness of the future limitations of Gas heating, rising costs, and future phase-outs and supply issues around gas based solutions, many companies have already begun swapping out their gas-based heating systems for heat pump solutions.  For swimming pools and home hot water systems, this process is relatively easy.  However, the commercial and process arena has been a challenging one for the same gas-to-heat pump exchange over.

This challenge has been the temperature output limitations of heat pumps. Gas-based solutions easily manage 65 to 90 Degree Celsius outputs, whereas heat pumps have been limited to around 45 to 65 Degrees until recently. Still requiring gas or other heater backup systems.

Our Utlra high temperature heat pump solution can cater to projects from 65oC up to 85oC water outlet temperatures without the requirement for additional backup heaters.

Utilising a unique 2-stage cascade R410a & R134a system they can perform even under low ambient conditions. Coupled with their EVI + DC inverter system the heat pumps can perform from -35oC through to + 50oC ambient conditions. Offering up to 30% energy consumption savings over other more traditional heat pumps.

A cascade system uses R410A as a primary heat pump to draw energy from the air and use this energy as a preheat for the R134a refrigerant loop. This allows the R134a to run efficiently creating a stable temperature environment.

CO2 heat pumps were the first main solution to manage the high-temperature hot water solutions, However, the advantage of a 2-stage cascade system over a CO2 Heat Pump or in fact, other R134a Heat Pumps is the ability to work at low ambient temperatures, and at the same time produce sustainable output temperatures around 75 degrees all year round.

The extra compressor stage does increase the initial cost of the unit over that of other R134a heat pumps, though the extra capacity and stable high-temperature hot water output puts this system a step above them. With that said they are still more affordable than the current CO2 heat pumps that sit around 50 to 100 kW outputs.

Making the Toyesi 2-Stage Cascade heat pumps the ideal go-to solution between 65 to 85 Degrees Celcius hot water solutions.

2 stage cascade image - Solutions - High Temperature Heat Pumps

Key Features

  • Ideal for boiler system replacement systems
  • Ideal for hydronic and process heating
  • Extremely energy efficient with COP from 1.5 to 16 pending operational conditions.
  • Available in 5 standard models. 12.5 kW (1-Phase) & 25 kW, 50 kW, 65 kW & 110 kW (3-Phase)
  • Wide ambient air performance from -35oC through to +50oC Ambient conditions.
  • Unique 2-staged design (R410a + R134a) allows for a stable 75 to 80oC output.
  • Advanced defrost intelligence to minimise or produce no frosting in the bottom of the system.
  • Fast inverter heating system to reduce heating times up to 50%
  • High COP and 30% energy saving design over traditional heat pumps.
high temp heat pumps - Solutions - High Temperature Heat Pumps

Technical Information

Air & Water ConditionNominal 12.5 kWNominal 25 kWNominal 50 kWNominal 65 kWNominal 110 kW
20oC Ambient & 75oC Water14.4 kW28.8 kW57.6 kW72.0 kW115.2 kW
7oC Ambient & 75oC Water12.5 kW24.9 kW49.9 kW62.3 kW103.9 kW
thermace 1 scaled e1714714213152 300x74 - Solutions - High Temperature Heat Pumps

Ultra-High Temperature Heat Pumps 85oC

Ultra-High Temp Heat Pumps

Our imported high-temp inverter heat pumps can cater to projects from 65 oC to 85 oC water outlet temperatures without additional backup heaters.

Utilising a unique cascade R410A & R134a system they perform even under low ambient conditions.

Coupled with a unique EVI+DC Inverter system these heat pumps can perform from -35oC through to +50oC ambient conditions.

Offering 30% energy consumption savings over other more traditional heat pumps.

6 models nominal 14 kW, 28 kW, 55 kW, 70 kW, 115 kW and 140 kW.

Will ship Australia-wide - Supply only.

high temp heat pumps - Solutions - High Temperature Heat Pumps

Product Features

    • Designed for direct Gas system upgrade and thus ideal for boiler system replacement systems.
    • EVI+DC Inverter technology.
    • Smart EVI (Enhanced Vapor Injection) Inverter Controls regulate the compressor and fans which save up to 30% over traditional hot water heat pumps.
    • Smart Controls utalise the DC inverter, EEV & EVI technology that on first heat will save you 50% of the heating time over traditional heat pumps.
    • High COP and 30% energy-saving design over traditional heat pumps.
    • Extremely energy efficient with C.O.P from 1.5 to 16 pending operating conditions.
    • Available in 6 standard models nominal rating 14kW, 28kW, 55kW, 70kW, 115kW & 140 kW
    • Wide ambient air performance -35oC through to +50 oC
    • Unique 2-staged design (R410A + R134a) allows for a stable 75oC ~ 85oC output.
    • Operational Temperature Range -35oC to 50oC +
    • Advanced Defrost intelligence to minimise or produce no frosting in the bottom of the system.
    • Fast inverter heating system to reduce heating times by up to 50%
    • Link up to 8 in Master-Slave arrangement
    • Modbus RS485 for central control.
    • Over 58,000 Sold across Europe since 2002
    • Advanced Defrost Smart Control
    • Compact design – Smaller footprint than competitor systems.
    • Available in both outdoor prop fan and indoor ducted systems.
    • Suitable for Hotels, hospitals, Food Processing, Drinks Distillation Processes, Textile Industry, Printing Industry, Rinse Industry and other high-temperature required projects.

Technical Information

MODELSUMMER HEATING
KW
WINTER HEATING
KW
DischargePOWER
UHW030-014-SI14.412.9Side1 Phase
UHW060-028-S328.826.3Side3 Phase
UHW120-055-T357.652.6Top3-Phase
UHW150-068-T372.065.2Top3-Phase
UHW250-114-T3115.2108.5Top3-Phase
UHW300-138-T3140.0130.3Top3-Phase
Want to know more request a quote: Click Here

Who can use Ultra-High Temperature Heat Pumps?

Anyone who is looking to upgrade from a gas-boiler system, or has a process system that requires temperatures above 75 degrees.

  • Hotels
  • Hospitals
  • Food processing
  • Textile industry
  • Printing Industry
  • Rinse Industry
  • Processing Solutions
  • Greenhouses
  • Metal plating systems
  • etc.
opotuntiess - Solutions - High Temperature Heat Pumps

Looking for Something Else?

Relax with Toyesi Heat Pumps
The hard work has been done for you.

Australia’s most reliable manufacturer of technically advanced commercial quality
HEATER-CHILLER HEAT PUMPS…
Unmatched For Technical Expertise & Meticulous Manufacturing

Personalised sizing and quotation?

CALL US DIRECT OR SHOOT US AN EMAIL

SALES & MARKETING

info@toyesi.com.au

DIRECT (AU) LINE

+(612) 9679 9400

SERVICE & ENGINEERING

peter.savtchenko@toyesi.com.au

Get a Quote*

Fill out the following form, our expert team will contact and make sure you
get the highest level of assistance

EFFICIENT ⚭ ECONOMICAL ⚭ PERFORMANCE

TOYESI PTY LTD.

2/27 Binney Road, Kings Park
NSW 2148, Australia
ARC Licence RTA AU02886
Email: toyesi@toyesi.com.au
Phone: (612) 9679 9400
Phone: (612) 9679 9402

Copyright © 2019 All Rights Reserved

Contact Us

We're not around right now. But you can send us an email and we'll get back to you, asap.

Not readable? Change text. captcha txt